Description
In the Linux kernel, the following vulnerability has been resolved:
nvme: Do not drop the cdev reference twice when cdev_device_add() fails
Since commit 9952f3882ecb ("nvme: fix cdev lifetime"),
nvme_add_ns_cdev() and nvme_add_ns_head_cdev() take a reference to the
namespace (or namespace head) before calling nvme_cdev_add(), to be
dropped by the char device's release, nvme_cdev_rel(), and drop it
themselves when nvme_cdev_add() fails. But when cdev_device_add()
fails, nvme_cdev_add() has already put the device, and nvme_cdev_rel()
has already dropped that reference: the caller drops it a second time.
With one allocation failure injected into cdev_device_add() for a
namespace on an NVMe over loop controller, deleting the controller
gives, with native multipath:
BUG: KASAN: slab-use-after-free in nvme_put_ns_head+0x21/0x140
Write of size 4 at addr ff1100000a4ea078 by task init/1
nvme_put_ns_head
nvme_put_ns
nvme_remove_namespaces
nvme_do_delete_ctrl
nvme_delete_ctrl_sync
nvme_sysfs_delete
Freed by task 1:
kfree
nvme_ns_remove
nvme_remove_namespaces
refcount_t: underflow; use-after-free.
Take the reference in nvme_cdev_add() instead, right before
cdev_device_add(), and let the callers neither take nor drop it. Add
nvme_is_ns_cdev() for the check that nvme_cdev_rel() and nvme_cdev_add()
now share.
nvme: Do not drop the cdev reference twice when cdev_device_add() fails
Since commit 9952f3882ecb ("nvme: fix cdev lifetime"),
nvme_add_ns_cdev() and nvme_add_ns_head_cdev() take a reference to the
namespace (or namespace head) before calling nvme_cdev_add(), to be
dropped by the char device's release, nvme_cdev_rel(), and drop it
themselves when nvme_cdev_add() fails. But when cdev_device_add()
fails, nvme_cdev_add() has already put the device, and nvme_cdev_rel()
has already dropped that reference: the caller drops it a second time.
With one allocation failure injected into cdev_device_add() for a
namespace on an NVMe over loop controller, deleting the controller
gives, with native multipath:
BUG: KASAN: slab-use-after-free in nvme_put_ns_head+0x21/0x140
Write of size 4 at addr ff1100000a4ea078 by task init/1
nvme_put_ns_head
nvme_put_ns
nvme_remove_namespaces
nvme_do_delete_ctrl
nvme_delete_ctrl_sync
nvme_sysfs_delete
Freed by task 1:
kfree
nvme_ns_remove
nvme_remove_namespaces
refcount_t: underflow; use-after-free.
Take the reference in nvme_cdev_add() instead, right before
cdev_device_add(), and let the callers neither take nor drop it. Add
nvme_is_ns_cdev() for the check that nvme_cdev_rel() and nvme_cdev_add()
now share.
Published:
2026-11-20
Score:
n/a
EPSS:
n/a
KEV:
No
Impact:
n/a
Action:
n/a
Analysis and contextual insights are available on OpenCVE Cloud.
Remediation
No vendor fix or workaround currently provided.
Additional remediation guidance may be available on OpenCVE Cloud.
Tracking
Sign in to view the affected projects.
Advisories
No advisories yet.
References
History
Fri, 20 Nov 2026 06:00:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Description | In the Linux kernel, the following vulnerability has been resolved: nvme: Do not drop the cdev reference twice when cdev_device_add() fails Since commit 9952f3882ecb ("nvme: fix cdev lifetime"), nvme_add_ns_cdev() and nvme_add_ns_head_cdev() take a reference to the namespace (or namespace head) before calling nvme_cdev_add(), to be dropped by the char device's release, nvme_cdev_rel(), and drop it themselves when nvme_cdev_add() fails. But when cdev_device_add() fails, nvme_cdev_add() has already put the device, and nvme_cdev_rel() has already dropped that reference: the caller drops it a second time. With one allocation failure injected into cdev_device_add() for a namespace on an NVMe over loop controller, deleting the controller gives, with native multipath: BUG: KASAN: slab-use-after-free in nvme_put_ns_head+0x21/0x140 Write of size 4 at addr ff1100000a4ea078 by task init/1 nvme_put_ns_head nvme_put_ns nvme_remove_namespaces nvme_do_delete_ctrl nvme_delete_ctrl_sync nvme_sysfs_delete Freed by task 1: kfree nvme_ns_remove nvme_remove_namespaces refcount_t: underflow; use-after-free. Take the reference in nvme_cdev_add() instead, right before cdev_device_add(), and let the callers neither take nor drop it. Add nvme_is_ns_cdev() for the check that nvme_cdev_rel() and nvme_cdev_add() now share. | |
| Title | nvme: Do not drop the cdev reference twice when cdev_device_add() fails | |
| First Time appeared |
Linux
Linux linux Kernel |
|
| CPEs | cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:* | |
| Vendors & Products |
Linux
Linux linux Kernel |
|
| References |
|
Status: PUBLISHED
Assigner: Linux
Published:
Updated: 2026-11-20T05:50:53.082Z
Reserved: 2026-09-25T10:25:14.430Z
Link: CVE-2026-99714
No data.
Status : Received
Published: 2026-11-20T06:18:07.677
Modified: 2026-11-20T06:18:07.677
Link: CVE-2026-99714
No data.
OpenCVE Enrichment
No data.
Weaknesses
No weakness.