| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC model chargers before version 24120701.
Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete
files and services.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC model chargers before version 24120701
Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete
files and services. |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root
This issue affects firmware versions before 24120701.
Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete
files and services.
CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y). |
| Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user.
This issue affects Iocharger firmware for AC models before version 24120701.
Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y). |
| Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user.
This issue affects Iocharger firmware for AC models before version 24120701.
Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H). A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y). |
| Use of a hard-coded password for a database administrator account created during Wapro ERP installation allows an attacker to retrieve embedded sensitive data stored in the database. The password is same among all Wapro ERP installations. This issue affects Wapro ERP Desktop versions before 8.90.0. |
| This vulnerability exists in Digisol Router (DG-GR1321: Hardware version 3.7L; Firmware version : v3.2.02) due to lack of encryption or hashing in storing of passwords within the router's firmware/ database. An attacker with physical access could exploit this by extracting the firmware and reverse engineer the binary data to access the plaintext passwords on the vulnerable system.
Successful exploitation of this vulnerability could allow the attacker to gain unauthorized access to the targeted system. |
| A hard-coded password in the FileCatalyst TransferAgent can be found which can be used to unlock the keystore from which contents may be read out, for example, the private key for certificates. Exploit of this vulnerability could lead to a machine-in-the-middle (MiTM) attack against users of the agent. This issue affects all versions of FileCatalyst Direct from 3.8.10 Build 138 and earlier and all versions of FileCatalyst Workflow from 5.1.6 Build 130 and earlier. |
| Argo Workflows Chart is used to set up argo and its needed dependencies through one command. Prior to 0.44.0, the workflow-role has excessive privileges, the worst being create pods/exec, which will allow kubectl exec into any Pod in the same namespace, i.e. arbitrary code execution within those Pods. If a user can be made to run a malicious template, their whole namespace can be compromised. This affects versions of the argo-workflows Chart that use appVersion: 3.4 and above, which no longer need these permissions for the only available Executor, Emissary. It could also affect users below 3.4 depending on their choice of Executor in those versions. This only affects the Helm Chart and not the upstream manifests. This vulnerability is fixed in 0.44.0. |
| The WP Mail SMTP plugin for WordPress is vulnerable to information exposure in all versions up to, and including, 4.0.1. This is due to plugin providing the SMTP password in the SMTP Password field when viewing the settings. This makes it possible for authenticated attackers, with administrative-level access and above, to view the SMTP password for the supplied server. Although this would not be useful for attackers in most cases, if an administrator account becomes compromised this could be useful information to an attacker in a limited environment. |
| A vulnerability in APIML Spring Cloud Gateway which leverages user privileges by unexpected signing proxied request by Zowe's client certificate. This allows access to a user to the endpoints requiring an internal client certificate without any credentials. It could lead to managing components in there and allow an attacker to handle the whole communication including user credentials. |
| A vulnerability has been found in FAST/TOOLS and CI Server. The affected products have built-in accounts with no passwords set. Therefore, if the product is operated without a password set by default, an attacker can break into the affected product.
The affected products and versions are as follows:
FAST/TOOLS (Packages: RVSVRN, UNSVRN, HMIWEB, FTEES, HMIMOB) R9.01 to R10.04
CI Server R1.01.00 to R1.03.00 |
| An issue in Solar-Log 1000 before v2.8.2 and build 52-23.04.2013 was discovered to store plaintext passwords in the export.html, email.html, and sms.html files -- fixed with 3.0.0-60 11.10.2013 for SL 200, 500, 1000 / not existing for SL 250, 300, 1200, 2000, SL 50 Gateway, SL Base. |
| A potential vulnerability was reported in some Lenovo Tablets that could allow a local authenticated user or application to gain access to sensitive device specific information. |
| A vulnerability has been found in Zytec Dalian Zhuoyun Technology Central Authentication Service 3. Affected by this vulnerability is an unknown functionality of the file /index.php/auth/Ops/git of the component HTTP Header Handler. The manipulation of the argument Authorization leads to use of hard-coded password. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). Affected devices store user passwords in plaintext without proper protection. This could allow a physical attacker to retrieve them from the embedded storage ICs. |
| BAS-IP AV-01D, AV-01MD, AV-01MFD, AV-01ED, AV-01KD, AV-01BD, AV-01KBD, AV-02D, AV-02IDE, AV-02IDR, AV-02IPD, AV-02FDE, AV-02FDR, AV-03D, AV-03BD, AV-04AFD, AV-04ASD, AV-04FD, AV-04SD, AV-05FD, AV-05SD, AA-07BD, AA-07BDI, BA-04BD, BA-04MD, BA-08BD, BA-08MD, BA-12BD, BA-12MD, CR-02BD before firmware v3.9.2 allows authenticated attackers to read SIP account passwords via a crafted GET request. |
| A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions < V2020 SP2 Update 5), SIMATIC Information Server 2022 (All versions < V2022 SP1 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC06), SIMATIC Process Historian 2020 (All versions < V2020 SP2 Update 5), SIMATIC Process Historian 2022 (All versions < V2022 SP1 Update 2), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 3), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 18), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products run their DB server with elevated privileges which could allow an authenticated attacker to execute arbitrary OS commands with administrative privileges. |
| Storing Passwords in a Recoverable Format vulnerability in Automated Logic WebCTRL on Windows, Carrier i-Vu on Windows. Storing Passwords in a Recoverable Format vulnerability (CWE-257) in the Web session management component allows an attacker to access stored passwords in a recoverable format which makes them subject to password reuse attacks by malicious users.This issue affects WebCTRL: from 6.0 through 9.0; i-Vu: from 6.0 through 9.0. |
| Under certain circumstances the web interface users credentials may be recovered by an authenticated user. |