| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An issue was discovered in Pivotal PCF Tile Generator versions prior to 6.0.0. Tiles created by the PCF Tile Generator create a running open security group that overrides security groups set by the operator. |
| Ubiquiti UniFi Video before 3.8.0 for Windows uses weak permissions for the installation directory, which allows local users to gain SYSTEM privileges via a Trojan horse taskkill.exe file. |
| Parameterized Trigger Plugin fails to check Item/Build permission: The Parameterized Trigger Plugin did not check the build authentication it was running as and allowed triggering any other project in Jenkins. |
| Builds in Jenkins are associated with an authentication that controls the permissions that the build has to interact with other elements in Jenkins. The Pipeline: Build Step Plugin did not check the build authentication it was running as and allowed triggering any other project in Jenkins. |
| Synology Download Station 3.8.x before 3.8.5-3475 and 3.x before 3.5-2984 uses weak permissions (0777) for ui/dlm/btsearch directory, which allows remote authenticated users to execute arbitrary code by uploading an executable via unspecified vectors. |
| HashiCorp Vagrant VMware Fusion plugin (aka vagrant-vmware-fusion) before 4.0.24 uses weak permissions for the sudo helper scripts, allows local users to execute arbitrary code with root privileges by overwriting one of the scripts. |
| An issue was discovered in Veritas NetBackup Before 7.7 and NetBackup Appliance Before 2.7. There are world-writable log files, allowing destruction or spoofing of log data. |
| An Incorrect Default Permissions issue was discovered in Schneider Electric Wonderware InduSoft Web Studio v8.0 Patch 3 and prior versions. Upon installation, Wonderware InduSoft Web Studio creates a new directory and two files, which are placed in the system's path and can be manipulated by non-administrators. This could allow an authenticated user to escalate his or her privileges. |
| Internet Explorer in Windows 10 Gold, 1511, 1607, 1703, and Windows Server 2016 allows an attacker to bypass Device Guard User Mode Code Integrity (UMCI) policies due to Internet Explorer failing to validate UMCI policies, aka "Internet Explorer Security Feature Bypass Vulnerability". |
| Atlassian Confluence starting with 4.3.0 before 6.2.1 did not check if a user had permission to view a page when creating a workbox notification about new comments. An attacker who can login to Confluence could receive workbox notifications, which contain the content of comments, for comments added to a page after they started watching it even if they do not have permission to view the page itself. |
| An issue was discovered in Logpoint 7.1 before 7.1.2. The daily executed cron file clean_secbi_old_logs is writable by all users and is executed as root, leading to privilege escalation. |
| Sourcecodester Human Resource Management System 1.0 is vulnerable to Insecure Permissions resulting in privilege escalation. |
| Insecure permission vulnerability in /hrm/leaverequest.php in SourceCodester Human Resource Management System 1.0 allow attackers to approve or reject leave ticket. |
| Sysmac Studio installs executables in a directory with poor permissions. This can allow a locally-authenticated attacker to overwrite files which will result in code execution with privileges of a different user. |
| Apiman 1.5.7 through 2.2.3.Final has insufficient checks for read permissions within the Apiman Manager REST API. The root cause of the issue is the Apiman project's accidental acceptance of a large contribution that was not fully compatible with the security model of Apiman versions before 3.0.0.Final. Because of this, 3.0.0.Final is not affected by the vulnerability. |
| Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition. |
| The security descriptor of Measuresoft ScadaPro Server version 6.7 has inconsistent permissions, which could allow a local user with limited privileges to modify the service binary path and start malicious commands with SYSTEM privileges. |
| An issue was discovered in Elspec G5 digital fault recorder versions 1.1.4.15 and before. The shadow file is world readable. |
| WIN-911 2021 R1 and R2 are vulnerable to a permissions misconfiguration that may allow an attacker to locally write files to the Program Announcer directory and elevate permissions whenever the program is executed. |
| WIN-911 2021 R1 and R2 are vulnerable to a permissions misconfiguration that may allow an attacker to locally write files to the program Operator Workspace directory, which holds DLL files and executables. A low-privilege attacker could write a malicious DLL file to the Operator Workspace directory to achieve privilege escalation and the permissions of the user running the program. |