Search Results (24681 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-11964 2 Microsoft, Tcpdump 2 Windows, Libpcap 2026-04-15 1.9 Low
On Windows only, if libpcap needs to convert a Windows error message to UTF-8 and the message includes characters that UTF-8 represents using 4 bytes, utf_16le_to_utf_8_truncated() can write data beyond the end of the provided buffer.
CVE-2023-44976 2026-04-15 3.2 Low
Hangzhou Shunwang Rentdrv2 before 2024-12-24 allows local users to terminate EDR processes and possibly have unspecified other impact via DeviceIoControl with control code 0x22E010, as exploited in the wild in October 2023.
CVE-2024-9977 1 Mitrastar 1 Gpt-2541gnac 2026-04-15 4.7 Medium
A vulnerability, which was classified as critical, was found in MitraStar GPT-2541GNAC BR_g5.6_1.11(WVK.0)b26. Affected is an unknown function of the file /cgi-bin/settings-firewall.cgi of the component Firewall Settings Page. The manipulation of the argument SrcInterface leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. We tried to contact the vendor early about the disclosure but the official mail address was not working properly.
CVE-2024-9166 1 Atelmo 1 Atemio Am 520 Hd Firmware 2026-04-15 N/A
The device enables an unauthorized attacker to execute system commands with elevated privileges. This exploit is facilitated through the use of the 'getcommand' query within the application, allowing the attacker to gain root access.
CVE-2023-51454 2026-04-15 6.8 Medium
A Out-of-bounds Write issue affecting the v2_sdk_service running on a set of DJI drone devices on the port 10000 could allow an attacker to overwrite a pointer in the process memory through a crafted payload triggering an unsafe memory write operation in the my_tcp_receive function implemented in the libv2_sdk.so library used by the dji_vtwo_sdk binary implementing the service, potentially leading to a memory information leak or to an arbitrary code execution. Affected models are Mavic 3 Pro until v01.01.0300, Mavic 3 until v01.00.1200, Mavic 3 Classic until v01.00.0500, Mavic 3 Enterprise until v07.01.10.03, Matrice 300 until v57.00.01.00, Matrice M30 until v07.01.0022 and Mini 3 Pro until v01.00.0620.
CVE-2024-9140 2026-04-15 9.8 Critical
Moxa’s cellular routers, secure routers, and network security appliances are affected by a critical vulnerability, CVE-2024-9140. This vulnerability allows OS command injection due to improperly restricted commands, potentially enabling attackers to execute arbitrary code. This poses a significant risk to the system’s security and functionality.
CVE-2024-9139 1 Moxa 8 Edf-g1002-bp Firmware, Edr-8010 Firmware, Edr-810 Firmware and 5 more 2026-04-15 7.2 High
The affected product permits OS command injection through improperly restricted commands, potentially allowing attackers to execute arbitrary code.
CVE-2024-43657 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2022-50909 1 Algosolutions 1 Algo 8028 2026-04-15 8.8 High
Algo 8028 Control Panel version 3.3.3 contains a command injection vulnerability in the fm-data.lua endpoint that allows authenticated attackers to execute arbitrary commands. Attackers can exploit the insecure 'source' parameter by injecting commands that are executed with root privileges, enabling remote code execution through a crafted POST request.
CVE-2023-29929 1 Kemptechnologies 1 Loadmaster 2026-04-15 7.5 High
Buffer Overflow vulnerability found in Kemptechnologies Loadmaster before v.7.2.60.0 allows a remote attacker to casue a denial of service via the libkemplink.so, isreverse library.
CVE-2024-9042 1 Redhat 1 Windows Machine Config 2026-04-15 5.9 Medium
This CVE affects only Windows worker nodes. Your worker node is vulnerable to this issue if it is running one of the affected versions listed below.
CVE-2024-43656 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43655 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-8934 1 Beckhoff 1 Twincat Packet Manager 2026-04-15 6.5 Medium
A local user with administrative access rights can enter specialy crafted values for settings at the user interface (UI) of the TwinCAT Package Manager which then causes arbitrary OS commands to be executed.
CVE-2025-12052 1 Insyde 1 Insydeh2o 2026-04-15 7.8 High
The drivers in the tool packages use RTL_QUERY_REGISTRY_DIRECT flag to read a registry value to which an untrusted user-mode application may be able to cause a buffer overflow.
CVE-2024-43654 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-8894 2026-04-15 N/A
Out-of-bounds Write vulnerability was discovered in Open Design Alliance Drawings SDK before 2025.10. Reading crafted DWF file and missing proper checks on received SectionIterator data can trigger an unhandled exception. This can allow attackers to cause a crash, potentially enabling a denial-of-service attack (Crash, Exit, or Restart) or possible code execution.
CVE-2024-43653 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability  allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-12248 2026-04-15 9.8 Critical
Contec Health CMS8000 Patient Monitor is vulnerable to an out-of-bounds write, which could allow an attacker to send specially formatted UDP requests in order to write arbitrary data. This could result in remote code execution.
CVE-2024-43652 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.