| CVE-2021-33882 | 1 Bbraun | 3 Infusomat Large Volume Pump 871305u, Spacecom2, Spacestation 8713142u | 2024-11-21 | 6.8 Medium |
| A Missing Authentication for Critical Function vulnerability in B. Braun SpaceCom2 prior to 012U000062 allows a remote attacker to reconfigure the device from an unknown source because of lack of authentication on proprietary networking commands. | ||||
| CVE-2020-25174 | 1 Bbraun | 1 Onlinesuite Application Package | 2024-11-21 | 7.8 High |
| A DLL hijacking vulnerability in the B. Braun OnlineSuite Version AP 3.0 and earlier allows local attackers to execute code on the system as a high privileged user. | ||||
| CVE-2020-25172 | 1 Bbraun | 1 Onlinesuite Application Package | 2024-11-21 | 9.8 Critical |
| A relative path traversal attack in the B. Braun OnlineSuite Version AP 3.0 and earlier allows unauthenticated attackers to upload or download arbitrary files. | ||||
| CVE-2020-25170 | 1 Bbraun | 1 Onlinesuite Application Package | 2024-11-21 | 7.8 High |
| An Excel Macro Injection vulnerability exists in the export feature in the B. Braun OnlineSuite Version AP 3.0 and earlier via multiple input fields that are mishandled in an Excel export. | ||||