| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Archive::Tar versions before 3.08 for Perl extract hardlinks to attacker controlled paths outside the extraction directory.
_make_special_file() passes the tar header's linkname to link() without validating it against absolute paths or .. segments, creating a hardlink that shares the victim file's inode.
A subsequent write through the extracted name modifies the victim file, and the post-extraction chmod, chown, and utime block in _extract_file() (guarded only against symlinks via -l) applies the tar header's mode, owner, and timestamps to the shared inode during extraction alone. |
| Archive::Tar versions before 3.08 for Perl extract symlinks with attacker controlled targets outside the extraction directory.
_make_special_file() passes the tar header's linkname to symlink() without validating it against absolute paths or .. segments. The secure-extract mode check that guards regular file extraction does not cover the symlink target.
A subsequent open through the extracted name reads or writes the attacker chosen path. |
| The HTTPPasswordMgr class in the urllib.request module, along with its subclasses HTTPPasswordMgrWithDefaultRealm and HTTPPasswordMgrWithPriorAuth, did not take the URL scheme into account when matching stored credentials against a requested URL. Credentials added for an https:// URL were also used for requests to the same host over http://, so an attacker able to redirect or downgrade a client to plain HTTP (for example, via an HTTPS-to-HTTP redirect or an on-path position) could capture credentials in cleartext. Credentials added for http:// URLs could likewise be sent over https://.
Credential matching is now scoped by URL scheme. Credentials registered with a URL that includes a scheme are only used for requests with the same scheme. Credentials registered with a bare authority (such as example.com or example.com:8080) continue to match any scheme, preserving compatibility with existing code, including proxy authentication.
Users who cannot upgrade immediately can mitigate by ensuring that applications never make plain http:// requests to hosts for which credentials are registered, for example by not following redirects to http:// URLs. |
| A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions < V6.0.0.0), TIA Portal Cloud V18 (All versions < V6.3.0.2), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2). Affected products do not properly sanitize stored security properties when parsing project files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. |
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V11.0), SIPROTEC 5 6MD85 (CP300) (All versions < V11.0), SIPROTEC 5 6MD86 (CP300) (All versions < V11.0), SIPROTEC 5 6MD89 (CP300) (All versions < V11.0), SIPROTEC 5 6MD89 (CP300) V9.6x (All versions < V11.0), SIPROTEC 5 6MU85 (CP300) (All versions < V11.0), SIPROTEC 5 7KE85 (CP300) (All versions < V11.0), SIPROTEC 5 7SA82 (CP100) (All versions < V8.91), SIPROTEC 5 7SA82 (CP150) (All versions < V11.0), SIPROTEC 5 7SA86 (CP300) (All versions < V11.0), SIPROTEC 5 7SA87 (CP300) (All versions < V11.0), SIPROTEC 5 7SD82 (CP100) (All versions < V8.91), SIPROTEC 5 7SD82 (CP150) (All versions < V11.0), SIPROTEC 5 7SD86 (CP300) (All versions < V11.0), SIPROTEC 5 7SD87 (CP300) (All versions < V11.0), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.91), SIPROTEC 5 7SJ81 (CP150) (All versions < V11.0), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.91), SIPROTEC 5 7SJ82 (CP150) (All versions < V11.0), SIPROTEC 5 7SJ85 (CP300) (All versions < V11.0), SIPROTEC 5 7SJ86 (CP300) (All versions < V11.0), SIPROTEC 5 7SK82 (CP100) (All versions < V8.91), SIPROTEC 5 7SK82 (CP150) (All versions < V11.0), SIPROTEC 5 7SK85 (CP300) (All versions < V11.0), SIPROTEC 5 7SL82 (CP100) (All versions < V8.91), SIPROTEC 5 7SL82 (CP150) (All versions < V11.0), SIPROTEC 5 7SL86 (CP300) (All versions < V11.0), SIPROTEC 5 7SL87 (CP300) (All versions < V11.0), SIPROTEC 5 7SS85 (CP300) (All versions < V11.0), SIPROTEC 5 7ST85 (CP300) (All versions < V11.0), SIPROTEC 5 7ST86 (CP300) (All versions < V11.0), SIPROTEC 5 7SX82 (CP150) (All versions < V11.0), SIPROTEC 5 7SX85 (CP300) (All versions < V11.0), SIPROTEC 5 7SY82 (CP150) (All versions < V11.0), SIPROTEC 5 7UM85 (CP300) (All versions < V11.0), SIPROTEC 5 7UT82 (CP100) (All versions < V8.91), SIPROTEC 5 7UT82 (CP150) (All versions < V11.0), SIPROTEC 5 7UT85 (CP300) (All versions < V11.0), SIPROTEC 5 7UT86 (CP300) (All versions < V11.0), SIPROTEC 5 7UT87 (CP300) (All versions < V11.0), SIPROTEC 5 7VE85 (CP300) (All versions < V11.0), SIPROTEC 5 7VK87 (CP300) (All versions < V11.0), SIPROTEC 5 7VU85 (CP300) (All versions < V11.0), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V11.0). The affected devices include session identifiers in URL requests for certain functionalities. This could allow an attacker to retrieve sensitive session data from browser history, logs, or other storage mechanisms, potentially leading to unauthorized access. |
| A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions < V17 Update 9), SIMOTION SCOUT TIA V5.5 (All versions < V18 Update 6), SIMOTION SCOUT TIA V5.6 (All versions < V19 Update 4), SIMOTION SCOUT TIA V5.7 (All versions < V20 Update 4), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions < V6.0.0.0), TIA Portal Cloud V18 (All versions < V6.3.0.2), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2), TIA Portal Test Suite V20 (All versions < V20 Update 4). Affected products do not properly sanitize Interprocess Communication input received through a Windows Named Pipe accessible to all local users. This could allow an authenticated local attacker to cause a type confusion and execute arbitrary code within the affected application. |
| A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 9), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 6), SIMATIC STEP 7 Safety V19 (All versions < V19 Update 4), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions < V17 Update 9), SIMATIC WinCC Unified V18 (All versions < V18 Update 6), SIMATIC WinCC Unified V19 (All versions < V19 Update 4), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOTION SCOUT TIA V5.4 (All versions < V17 Update 9), SIMOTION SCOUT TIA V5.5 (All versions < V18 Update 6), SIMOTION SCOUT TIA V5.6 (All versions < V19 Update 4), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions < V18 Update 6), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions < V6.0.0.0), TIA Portal Cloud V18 (All versions < V6.3.0.2), TIA Portal Cloud V19 (All versions < V5.2.1.1). Affected products do not properly sanitize user-controllable input when parsing log files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. |
| The Appointment Booking Calendar Plugin and Scheduling Plugin WordPress plugin through 1.1.28 does not validate data before passing it to a PHP deserialization function, allowing unauthenticated attackers to inject arbitrary PHP objects; where a suitable gadget chain is present on the site this can be leveraged to achieve remote code execution. |
| The Everest Forms WordPress plugin before 3.5.0 does not reliably delete temporary CSV files generated during email-notification processing and leaves them publicly accessible in the uploads directory, allowing unauthenticated attackers to retrieve other users' form submission records via predictable, enumerable filenames. |
| Deserialization of Untrusted Data vulnerability in ShapedPlugin LLC Real Testimonials testimonial-free allows Object Injection.This issue affects Real Testimonials: from n/a through <= 3.1.15. |
| The Newsletters WordPress plugin before 4.15 does not prevent deserialization of untrusted input that is stored through a public form, allowing unauthenticated attackers to inject a PHP object and, via a property-oriented gadget chain bundled with the Newsletters WordPress plugin before 4.15, write arbitrary files and execute code on the server. |
| The Paid Membership Subscriptions WordPress plugin before 3.0.7 does not protect the member and payment export files it writes to a predictable location in the uploads directory, allowing unauthenticated users to download the exported member and payment data (including PII) while an export artifact is present. |
| The Kirki WordPress plugin before 6.0.13 does not restrict which classes may be instantiated when it deserialises data that unauthenticated users can store, leading to PHP Object Injection that is triggered when an administrator later reviews the stored data. With a suitable gadget chain present on the site (via another installed Kirki WordPress plugin before 6.0.13, , or an outdated WordPress version), this could be leveraged to perform a variety of attacks, such as remote code execution. |
| The LaserGest mobile application encrypts stored assistance portal credentials with a hardcoded AES key and IV, allowing an attacker with access to the application package to recover them in cleartext. |
| compose-lint is a Docker Compose security linter that identifies dangerous misconfigurations before deployment. From 0.2.0 until 0.25.0, compose-lint follows a project-controlled symbolic link used as the Compose file outside the project. The same issue affects compose.override.yml and a COMPOSE_FILE entry from 0.22.0, and an env_file target from 0.23.0. If an external Compose-related target fails YAML parsing, the error quotes an attacker-uncontrolled line into standard error, JSON errors, and SARIF notifications, while an external env_file can expose credential-like key names through CL-0020 and CL-0021 findings. The attacker selects the target path but not the exact parser-failure line, values from env_file are not printed, and the pass or fail result is unchanged. This issue is fixed in version 0.25.0. |
| Deserialization of untrusted data in .NET allows an unauthorized attacker to execute code over a network. |
| Deserialization of untrusted data in .NET Framework allows an unauthorized attacker to execute code over a network. |
| Improper link resolution before file access ('link following') in .NET allows an authorized attacker to elevate privileges locally. |
| Improper link resolution before file access ('link following') in .NET allows an authorized attacker to elevate privileges locally. |
| e107 is a content management system (CMS). Prior to 2.3.7, install.php decodes the attacker-controlled previous_steps POST parameter and passes it to unserialize() at file scope and again in the e_install constructor without restricting allowed classes. The installer remains accessible after a normal installation, and a crafted object graph using the bundled GuzzleHttp\Psr7\PumpStream class can flow through paths.hash into site_path, where string coercion invokes an attacker-controlled callable. An unauthenticated attacker who can reach install.php can therefore execute arbitrary PHP functions with the web server process's privileges, leading to full server compromise. This issue is fixed in version 2.3.7. |